Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensors: temperature, humidity, current. External sensors (included in the basic package): Digital sensor for active power and temperature, Digital temperature sensor with a length of 25 feet (7.62 meters). Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 8 ports for external temperature or temperature and humidity sensors. 16 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 2 ports for analog current sensors, relay (switch), signal tower. 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Mini UPS. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1 and V2 (soon V3). Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensors: temperature, humidity, current. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 8 ports for external temperature or temperature and humidity sensors. 16 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 2 ports for analog current sensors, relay (switch), signal tower. 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Mini UPS. Web interface for administration. Email notifications. SNMP. Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1 and V2 (soon V3). Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital sensor for active power and temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 3 ports for external temperature or temperature and humidity sensors. 4 ports for external sensors: smoke, flood, current, movement, open door, air flow, water level. 1 relay port (switch). 1 signal tower port (light tower adapter required). 1 10/100 ethernet port; Mount in a 19 '' rack. POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 1 port for external temperature or temperature and humidity sensor. 1 port for external sensor of: smoke, flood, current, movement, open door, air flow, water level. 1 10/100 ethernet port; POE (Power Over Ethernet). Web interface for administration. Email notifications. Web interface for administration (https). Email notifications (SSL / TLS). SNMP V1, V2 si V3. Made in USA.
It signals in real time, to the Room Alert server, the presence of fluids that come in contact with the sensor cable. Plug and play. 5VDC 1A DC adapter. Compatible with any Room Alert server. Length 8 feet (2,4384 meters).
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 1 port for external temperature or temperature and humidity sensor. 1 port for external sensor of: smoke, flood, current, movement, open door, air flow, water level. WiFi; Web interface for administration. Email notifications. SNMP. Made in USA.
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 1 port for external temperature or temperature and humidity sensor. 1 port for external sensor of: smoke, flood, current, movement, open door, air flow, water level. 1 10/100 ethernet port; POE (Power Over Ethernet). Web interface for administration. Email notifications. SNMP. Made in USA.
Signal the presence of water in real time to the Room Alert server. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Power a 9V Alkaline battery (included). Compatible with any Room Alert server.
It signals in real time, to the Room Alert server, the presence of fluids that come in contact with the sensor cable. Plug and play. 5VDC 1A DC adapter. Compatible with any Room Alert server. Length 24 feet (7,3152 meters).
Server for monitoring temperature, humidity, current, energy consumption, floods, smoke, fire, access, etc ... Internal sensor: temperature. External sensor (included in the basic package): Digital temperature sensor with a length of 25 feet (7.62 meters). Software included: Device ManageR Software, One year free upgrade to RoomAlert.com account. 2 ports for external temperature or temperature and humidity sensors. 1 port for external sensor of: smoke, flood, current, movement, open door, air flow, water level. 1 signal tower port. 1 10/100 ethernet port; Mount in a 19 '' rack. Web interface for administration. Email notifications. SNMP. Made in USA.
It signals in real time, to the Room Alert server, the presence of fluids that come in contact with the sensor cable. Plug and play. 5VDC 1A DC adapter. Compatible with any Room Alert server. Length 50 feet (15.24 meters).