DC temperature and voltage sensor

RMA-DTA-SEN
Measure in real time (every two seconds), in Volts, with the accuracy of +/- 0.075V, the DC voltage in the range (0, 5). Measures in real time (every two seconds), in degrees Celsius, with the accuracy of +/- 2 degrees C, temperatures in the range (-40, 85). Plug and play. RJ-11 connector. Compatible with any Room Alert server.
492,83 RON incl tax

Current intensity sensor (50A)

RMA-CL1-SEN
It measures the intensity of the single-phase electric current that passes through a power cable, with the accuracy of +/- 1.0% (5 to 100% FSO), in the range (0A, 50A). The range of measurable current frequencies is in the range (50 Hz, 600 Hz). Response time is <0.1 seconds. It connects to the analog port of the Room Alert server to send the measured intensity values. Standard cable length 25 feet (7.62 meters) extendable up to 100 feet (30.48 meters). Plug and play. Compatible with Room Alert 32E and Room Alert 32S. For other Room Alert servers, the Digital Temperature and DC Voltage Sensor (RMA-DTA-SEN) adapter is required.
492,83 RON incl tax

Current intensity sensor (250A)

RMA-CL2-SEN
It measures the intensity of the single-phase electric current that passes through a power cable, with the accuracy of +/- 1.0% (5 to 100% FSO), in the range (0A, 250A). The range of measurable current frequencies is in the range (50 Hz, 600 Hz). Response time is <0.1 seconds. It connects to the analog port of the Room Alert server to send the measured intensity values. Standard cable length 25 feet (7.62 meters) extendable up to 100 feet (30.48 meters). Plug and play. Compatible with Room Alert 32E and Room Alert 32S. For other Room Alert servers, the Digital Temperature and DC Voltage Sensor (RMA-DTA-SEN) adapter is required.
492,83 RON incl tax

Fuel level sensor in the tank (normal state: closed)

RMA-FTL1-SEN
It signals in real time, to the Room Alert server, the level of fuel or other viscous liquid (from a large tank), located between a configured minimum and maximum level. Level variations smaller than 10 inches (0.254 meters) are not noticed. Level variations larger than 50 inches (1.27 meters) are not noticeable. The cable and the float are adapted to the corrosive environment in which it operates. Normal condition: closed. Plug and play. Standard cable length 25 feet (7.62 meters) extendable up to 900 feet (274.32 meters). Compatible with any Room Alert server.
1.322,85 RON incl tax